Direct-to-chip liquid cooling cold plate

Engineered for next-generation AI accelerators — continuous heat removal at the semiconductor package, with a copper-matrix path from die to facility rejection.

Product overview

HEx is the Hayagreeva Exchange — a direct-to-chip cold plate that mounts on the accelerator package. Fluid removes waste heat at the die and transfers it through the rack manifold and CDU to the facility heat-rejection system.

Package-specific fitting, mounting, connectors, and fluid are required for NVIDIA, AMD, and Intel accelerator architectures.

Accelerator hardware prepared for thermal integration
5,000+ W
Continuous heat removal
0.005
°C/W rated thermal resistance
4,000+
m²/m³ wetted surface area
May '26
Product launch

Why Hayagreeva HEx

Rated at the die

Continuous heat removal above 5,000 W at 0.005 °C/W — capacity stated at the package, not averaged across the rack.

Copper matrix

Wetted surface density above 4,000 m²/m³ expands the heat-transfer interface at the chip boundary.

Facility-ready path

Chip → HEx → CDU → rejection. One path moves heat off the package and out of the building.

Performance

Rated thermal capacity and resistance are stated at the semiconductor package under defined test conditions. System-level performance depends on coolant properties, flow rate, inlet temperature, pressure drop, and package geometry.

5,000+ W
Continuous heat removal (rated at package)
0.005 °C/W
Rated thermal resistance
~25 °C
Implied ΔT at rated conditions
4,000+
m²/m³ wetted surface area

Technical specifications

Thermal capacity More than 5,000 W continuous heat removal (rated at package)
Thermal resistance 0.005 °C/W rated
Architecture Copper matrix with 4,000+ m²/m³ wetted surface area
Compatibility NVIDIA, AMD, and Intel accelerator architectures
Intellectual property 14 patent filings supporting the thermal design
Launch May 28, 2026

Exact results depend on coolant, flow rate, inlet temperature, and package geometry.

Validation & testing

Validated under stated conditions

Thermal performance is validated against stated test conditions. Rated metrics are separated from design targets. Contact engineering for NDA test documentation.

Test methodology Package-level thermal testing with documented coolant, flow, and inlet conditions
Claims policy No unsupported superlatives; patent filings referenced as filings unless granted

Applications

Data center server racks

Data centers

Hyperscale and colocation facilities running high-density AI racks.

Server platform hardware

OEM platforms

Server and accelerator platforms requiring package-specific thermal integration.

Engineering integration workspace

System integrators

Custom HPC and sovereign AI programs with facility-level cooling constraints.

High-performance computing infrastructure

HPC & AI

Sustained accelerator performance without thermal throttling under load.

Request a pilot evaluation

Open for qualified data-center operators, server OEMs, and integration partners.

Contact engineering